Still deciding? Get samples of $ !
Request Sample
|
| Customization: | Available |
|---|---|
| Transport Package: | Carton |
| Trademark: | Jiayi |
| Shipping Cost: | Contact the supplier about freight and estimated delivery time. |
|---|
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Jiayi Fire is a global supplier of high-quality firefighting equipment, providing reliable and cost-effective fire safety solutions to customers across Europe, Asia, the Middle East, Africa, and the Americas.
Our modern manufacturing facilities combine advanced technology with strict quality control to ensure reliable product performance and consistent quality. Our products serve industrial, commercial, and marine applications and meet relevant international standards.
We hold certifications including ISO, CE, TUV, RoHS, UKCA, ECM, and DIN. With professional service, competitive pricing, and OEM/customization capabilities, we are committed to building long-term partnerships with customers worldwide.

POWDER Fire Extinguisher
| Type | 1kg | 2kg | 6kg | 9kg | 12kg |
| Cylinder Size | D85*H270 | D110*H317 | D162*H422 | D184*H489 | D184*H581 |
| Capacity | 1.25L | 2.5L | 7.5L | 11.25L | 13.5L |
| Net Weight | 2.4kg | 4.1kg | 9.8kg | 14.2kg | 18kg |
| Working temp | -20ºC~60ºC | ||||
| Working Pressure | 14 Bar | ||||
| Test Pressure | 27 Bar | ||||
| Discharge Time(s) | 9s | 11s | 17s | 20s | |
| Fire Class | 8A 34B C | 13A 70B C | 34A 183B C | 55A 233B C | 55A 233B C |
| Packing Size(mm) | 490*250*370 | 370*270*415 | 170*170*560 | 205*200*610 | 210*200*700 |
CO2 Fire Extinguisher
| Type | 1.3kg/3lbs | 2kg | 3kg | 4.5kg/10lbs | 6kg | 7kg/15lbs |
| Cylinder Size (mm) | D108*H330 | D114*H420 | D114*H610 | D152*H520 | D152*H670 | D152*H760 |
| Wall Thickness (mm) | 4.2 | 4.5 | 5.5 | |||
| Cylinder weight | >3.90kg | >5.3kg | >7.3kg | >12.2kg | >13.5kg | >16.5kg |
| Capacity | 2L | 3L | 4.5L | 6.8L | 9L | 10.5L |
| Agent | >1.3kg CO2 | >2.0kg CO2 | 3.0kg CO2 | >4.4kg CO2 | 5.0kg CO2 | 7.0kg CO2 |
| Net Weight | 5.8kg | 7.8kg | 11kg | 17kg | 20.5kg | 25kg |
| Measurements (cm) | 16*13*46 | 17*13*55 | 17*13*72 | 23*17*64 | 22*17*79 | 22*17*88 |
| Operating Temperature | -20ºC to +60ºC | |||||
| Working pressure | ≤15Mpa | |||||
| Test pressure | 25MPa | |||||
| Burst pressure | ≥40Mpa | |||||
| Discharge time | ≥8s | ≥15s | ||||
| Discharge range | ≥2m | ≥2.5m | ||||
| Type | 500ML | 1L | 2L | 6L | 9L |
| Cylinder Material | SS304 | ST12 | |||
| Cylinder Weight (kg) | 0.4 | 0.53 | 0.75 | 2.7 | 3.2 |
| Cylinder Capacity (L) | 0.65 | 1.3 | 2.5 | 7.8 | 11.8 |
| Working Pressure | 14 Bar | ||||
| Test Pressure | 29 Bar | ||||
| Working temp | 0ºC to +60ºC | ||||
| Propellant gas | Nitrogen / N2 | ||||
| Declare fire rate | 3A 13B C | 1A 10B C | 8A 34B C | 1113B 89B | 113B |
| Packing Size (mm) | D75*H260 | D85*H340 | D102*H420 | D160*H550 | D180*H600 |
| Total Weight (kg) | 1.12 | 1.8 | 3.1 | 9.3 +/- 0.1 | 13.2 +/- 0.2 |
| Agent | 6% AFFF | ||||
| Type | 10kg | 12kg/25lbs | 20kg | 24kg | 30kg | 50kg |
| Cylinder Material | CK45 | 37Mn | ||||
| Wall Thickness (mm) | 5.5 | 6 | ||||
| Cylinder Weight (kg) | 19.5 | 25 | 50 | 55 | 60 | 100 |
| Capacity (L) | 15 | 18 | 30 | 36 | 45 | 80 |
| Filling With CO2 (kg) | 10 | 12 | 20 | 24 | 30 | 50 |
| Net Weight (kg) | 39 | 46 | 95 | 100 | 120 | 195 |
| Measurement (cm) | 38*28*115 | 38*28*132 | 110*50*110 | 110*50*120 | 110*60*130 | 110*70*120 |
| Using Temperature | -20ºC to +60ºC | |||||
| Working Pressure | ≤15Mpa | |||||
| Test Pressure | 25MPa | |||||
| Burst Pressure | ≥40Mpa | |||||
| Discharge Time | ≥15s | |||||
| Discharge Range | ≥3 m | |||||

Class A rating fire extinguishers are often water-based, and are highly effective in extinguishing burning materials found or stored in an office or warehouse for example. Water-based Class A extinguishers may also have additives to make them more effective.
Class B rating fire extinguishers are usually foam fire extinguishers or powder. These extinguishers work by not only extinguishing flames but also sealing in any potentially dangerous vapours.
Class C rating fire extinguishers will be dry powder fire extinguishers that are capable of separating the elements of thee fire triangle.
Class D rating fire extinguishers are highly specialized extinguishers, designed to be used on specific metal fires with such exotic names as M28, L2 and Purple-K. They will have a long lance with a low velocity application on the end.
Class E rating fire extinguishers are specially designed for use on live electrical equipment. While a powder fire extinguisher is non-conductive and safe to use, the most popular fire extinguisher for use on electrical equipment fires is carbon dioxide, which extinguishes flames without causing further damage.
Class F rating fire extinguishers, also known as wet chemical fire extinguishers, are specifically for fires involving cooking oils and fats.

Q1. Do you provide customized products ?
A1. Yes, we do OEM and ODM, or we are open for any other requirement.
Q2. Do you provide sample for trial ?
A2. Yes, we can offer free sample.
Q3. What's the warranty ?
A3. Our products come with 6-month warranty period, and we provide one-stop after sales service to assist you solve all problems.
Q4. How long does it take for delivery ?
A4. The products will be ready for delivery within 20 to 25 days as usual after the payment.
Q5. What's the payment term ?
A5. We accept L/C, T/T, D/P, PayPal, Western Union, etc.